10-80 IM 701450-01E
Viewing the Details of the Analysis Data
30. Press the Detail soft key. A Detail dialog box opens. The analysis data of the same
analysis number that is highlighted in the list in step 24 or 28 is displayed highlighted.
31. Press the Hex or Bin soft key to select the notation used to display the analysis
data (Data1 and Data2).
If indefinite data exists in the analysis data, “” is attached to the corresponding data.
32. Press ESC. The Detail dialog box closes.
Analysis
number
Data2 value (hexadecimal or binary)
Data1 value (hexadecimal or binary)
Time from the
reference point
CS signal status or the name of the
CS signal whose priority is high
Note
The detailed analysis list can be saved directly to an external storage medium in ASCII (.txt
extension) format. For details, see section 12.11, “Saving the Detailed Analysis List of SPI Signals.”
Searching the Analysis Data
Setting the Search Conditions
33. Press the Data Search soft key. The Data Search menu appears.
34. Press the Search Setup soft key. The Search Setup dialog box opens.
35. Use jog shuttle & SELECT to set the search type to Frame Pattern or Indefinite
State (Type box).
If you select Indefinite State, proceed to step 36.
36. Use jog shuttle & SELECT to set the notation system used to set the
determination pattern to Hex or Bin (Pattern Format box). The format in the
Data Pattern box is set to the format that matches the selected result.
37. Use jog shuttle & SELECT to set the search target data to Data1 or Data2
(Source box).
If you selected Indefinite State in step 34, proceed to step 39.
38. Use jog shuttle & SELECT to set the data length of the determination pattern to be
specified from 1 to 8 bytes (Data Byte box). The number of bytes displayed in the Data
Pattern box is set to the number of bytes that matches the selected result.
10.11 Analyzing and Searching SPI Signals

Table of Contents

Other manuals for YOKOGAWA DL7440