486
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_read.fm
READ
READ:CFERror[:ALL]?
READ:CPOWer[:ALL]?
Function Initiates and fetches the FER (frame error rate) measurements as a sequential operation.
FER measurement results are returned in the following order: integrity, confidence limit
pass/fail result, frame error ratio, frame error count, frames tested.
Query Integrity
• Range: 0 to 23 see “Integrity Indicator”
• Resolution: 1
Confidence limit pass/fail result
• Range: 0 to 2 (0 = passed, 1 = failed, 2 = max frames), 9.91 E+37
Frame error ratio
• Range: 0.00 to 100.00, 9.91 E+37
• Resolution: 0.01 %
Frame error count
• Range: 0 to 10,000,000, 9.91 E+37
• Resolution: 1 frame
Frames tested
• Range: 0 to 10,000,000, 9.91 E+37
• Resolution: 1 frame
Function Initiates and fetches a channel power measurement as a sequential operation.
Measurement results are returned in the following order: integrity, average channel power.
If the multi-measurement state is on, the result represents the average of a number of channel
power measurements. Multi-measurement state, by default, is off. To set up
multi-measurements, see “SETup:CPOWer:COUNt[:SNUMber]” .
Query Integrity
• Range: 0 to 23 see “Integrity Indicator”
• Resolution: 1
Channel power
• Range: -100.00 to 100.00 dBm, 9.91 E+37
• Resolution: 0.01 dB