EasyManuals Logo

Agilent Technologies 8960 Series Reference Guide

Agilent Technologies 8960 Series
786 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #581 background imageLoading...
Page #581 background image
581
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_status_operation.fm
STATus:OPERation:
STATus:OPERation:CALL:COMMon Condition Register Bit Assignment
The STATus:OPERation:CALL:COMMon register bits will be used to indicate status of processes that occur
during normal call processing operations.
Bit
Number
Binary
Weighting
Condition Description
15 32768 Not Used. Defined by SCPI. This bit is always 0.
14 16384 Data Summary This bit is the summary message bit for the
STATus:QUEStionable:CALL:GSM:DATA register.
13 8192 Call Control Status Access Probe This bit is a 1 when the test set is in the call control
status access probe state.
12 4096 Call Control Status Set Up
Request
This bit is a 1 when the test set is in the call control
status set up request state.
11 2048 Call Control Status Releasing This bit is a 1 when the test set is in the call control
status releasing state.
10 1024 Call Control Status Paging This bit is a 1 when the test set is in the call control
status paging state.
9 512 Registering (BS initiated) This bit is set to a 1 when the Base Station initiates
registration.
8 256 Reserved for future use. This bit is always 0.
7 128 BS Originating This bit is a 1 when:
Active Cell mode - the call processing state
leaves the idle state
Test mode - the test set has noted a base station
origination.
6 64 Call Control Status Changing This bit is a 1 when the test set is in the call control
status changing state.
5 32 Call Control Status
Handover/Handoff
This bit is a 1 when the test set is in the call control
handover or handoff state.
4 16 Call Control Status Registering This bit will be a 1 when the test set is in the call
control status registering state.
3 8 Call Control Status is Alerting This bit is a 1 when the test set is in the call
alerting state (ringing).
2 4 Call Control Status is Connected This bit is a 1 when the test set is in the call
connected state.
1 2 Call Control Status is Idle This bit is a 1 when the test set is in the call idle
state.
0 1 Extension Bit This bit is always 0.

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers: