EasyManua.ls Logo

Agilent Technologies 8960 Series

Agilent Technologies 8960 Series
786 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
717
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_ts_ctxspurious.fm
Tx Spurious Emissions Measurement Troubleshooting
Tx Spurious Emissions Measurement Troubleshooting
Possible Setup Issues
IMPORTANT If the Access Probe Power measurement is currently selected and the Trigger Arm setting is
Continuous, all other measurements are disabled. Use the SETup:CAPPower:CONTinuous
command to set the trigger arm state to single and retry this measurement.
During remote operation of this measurement, you should configure the Trigger Arm to Single. See
SETup:CTXSpurious:CONTinuous . If single triggering is used during manual operation, press the START
SINGLE key to trigger each measurement.
The input signal must conform to Input Signal Requirements .
The test set receivers expected signal amplitude and channel number (or frequency) must be set up correctly
for accurate measurements. This is normally done automatically (see Active Cell Operating Mode ) but can
also be done manually (see Receiver Control on page 194) .
Related Topics
Integrity Indicator on page 222
Tx Spurious Emissions Measurement Description

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Related product manuals