100-412-234 REV. 06 147
6.10.26 Component Verify
Users can decide to match any of these assemblies with the saved assembly in the
Validated Preset screen before allowing a weld cycle. If any of assemblies are selected on
the above screen then the assembly in System Configuration will be matched with the
assembly in Validated Preset before starting a cycle. A Setup alarm will be generated in
case of any mis match and weld will not be allowed for that preset.
Figure 6.40 Component Verify
6.10.27 Freq Offset
Set whether the frequency offset is internally (Int) or externally (Ext) controlled.
6.10.28 Memory Full
Set whether the welding cycle will be allowed to run once the system’s internal memory is
full for Weld History or Events. If allowed to Run, the oldest cycle will be overwritten with
the next weld cycle. Memory can be cleared by using Copy Now and deleting memory.
NOTICE
Only Supervisor or Executive users can change these settings and
any change will be recorded in the event history log.
NOTICE
Only Supervisor or Executive users can change these settings.