100-412-234 REV. 06 251
23F
Cutoff
Conflict
The plus suspect power
limit is equal to or less than
the peak power cutoff
value.
Change the +suspect power
limit or peak power cutoff
through the Alarm Information
screen or Setup menu.
24A
Eng S/R
Limit Cross
The plus reject energy limit
is equal to or less than the
plus suspect energy limit.
Change the +reject energy
limit or +suspect energy limit
through the Alarm Information
screen or Setup menu.
24B
Eng S/R
Limit Cross
The minus reject energy
limit is equal to or greater
than the minus suspect
energy limit.
Change the - reject energy
limit or - suspect energy limit
through the Alarm Information
screen or Setup menu.
24C
Pwr S/R
Limit Cross
The plus reject power limit
is equal to or less than the
minus suspect power limit.
Change the +reject power limit
or - suspect power limit
through the Alarm Information
screen or Setup menu.
24D
Pwr S/R
Limit Cross
The plus reject power limit
is equal to or less than the
plus suspect power limit.
Change the +reject power limit
or +suspect power limit
through the Alarm Information
screen or Setup menu.
24E
Pwr S/R
Limit Cross
The plus suspect power
limit is equal to or less than
the minus reject power
limit.
Change the +suspect power
limit or - reject power limit
through the Alarm Information
screen or Setup menu.
24F
Pwr S/R
Limit Cross
The minus reject power
limit is equal to or greater
than the minus suspect
power limit.
Change the - reject power limit
or - suspect power limit
through the Alarm Information
screen or Setup menu.
25A
F S/R Limit
Cross
The plus reject force limit is
equal to or less than the
plus suspect force limit.
Change the +reject force limit
and/or the +suspect force limit
through the Alarm Information
screen or Setup menu.
25B
F S/R Limit
Cross
The minus reject force limit
is equal to or greater than
the minus suspect force
limit.
Change the - reject force limit
and/or the - suspect force limit
through the Alarm Information
screen or Setup menu.
26A
Missing Part
Conflict
The missing part minimum
is equal to or greater than
the missing part maximum
setting.
Change the missing part
minimum and/or the missing
part maximum setting through
the Alarm Information screen
or Setup menu.
26D
Pretrigger
Conflict
The pretrigger
distance is equal to or
greater than the minus
reject absolute limit.
Change the pretrigger distance
or - reject absolute limit
through the Alarm Information
screen or Setup menu.
Table B.5 Setup Alarms and Messages, with Probable Cause and Corrective Action (Continued)
Alarm
ID
Display
Message
Alarm Condition/Cause Corrective Action