256 100-412-234 REV. 06
2F1
Preset
Conflict
Both the external selection
of presets and sequencing
are turned on.
Turn off one of these.
2F2
Min Trigger
Conflict
The trigger force is set
below the minimum
allowable value.
Minimum trigger force is
changed after the trigger force
has been set, or if downloaded
via host command.
2F3
Sequence
Empty
Preset sequencing is
enabled and a start signal
has been received, but
there is o sequence defined.
Define sequence.
Table B.5 Setup Alarms and Messages, with Probable Cause and Corrective Action (Continued)
Alarm
ID
Display
Message
Alarm Condition/Cause Corrective Action