CHAPTER 6 KEYPAD
Test Operation Mode 6-47
6
(5) Alarm reset
The alarm currently detected in the servo amplifier is reset.
The servo amplifier is not reset from some alarms through alarm resetting. To reset these alarms,
turn the power off then on again.
Alarms removed through alarm resetting Alarms not removed through alarm resetting
Display Name Display Name
Overcurrent 1
Encoder Trouble 1
Overcurrent 2
Encoder Trouble 2
Overspeed
Circuit Trouble
Overvoltage
Motor Combination Error
Breaking Transistor
Overheat
Breaking Transistor
Overheat
Encoder
Communication Error
CONT(Control signal)Error
Overload 1
Breaking Transistor Error
Overload 2
Inrush Current Suppression
Circuit Trouble
Main Power
Undervoltage
Absolute Data Lost 1
Internal Breaking
Resistor Overheat
Absolute Data Lost 2
External Breaking
Resistor Overheat
Absolute Data Lost 3
Deviation Overflow
Absolute Data Over Flow
Amplifier Overheat
Initial Error
Encoder Overheat
Go
Fn05
AL
rt
ESC
SET
(1 sec. or over)
ESC
donE
SET
(1 sec. or over)
End of resetting
nG
SET
(1 sec. or over)
ESC
* For the cause of NG display, refer
to "NG display (common)" on page
6-43.
oS
cE
Hu
Et1
Et2
ct
oc2
oc1
Ec
oL1
tH
tH
ctE
rH3
DL1
DL2
DL3
AF
iE
LuP
rH1
rH2
oF
AH
EH
oL2
rH4