CHAPTER 14 PC LOADER
Parameter Conversion Tool 14-43
14
■ When “Yes” is selected with gain system parameter conversion, the motor models
before conversion and after conversion are dealt as the same in gain system parameter
conversion. Therefore, the data of motor model after conversion is set same as the motor
model before conversion.
Motor setting before conversion Motor setting after conversion Remarks
GYS500DC2-T2*-* GYS, GYC(750W or less)
GYS101DC2-T2*-*
GYS201DC2-T2*-*
GYS401DC2-T2*-*
GYS751DC2-T2*-*
GYG501CC2-T2*-* GYG(Rated rotation speed:2000r/min)
GYG751CC2-T2*-*
GYG102CC2-T2*-*
GYG152CC2-T2*-*
GYG202CC2-T2*-*
GYG501BC2-T2*-* GYG(Rated rotation speed:1500r/min)
GYG851BC2-T2*-*
GYG132BC2-T2*-*
GYG182BC2-T2*-* GYG182BC2-T2*-* Encoder. :17bit
GYG292BC2-T2*-* GYG292BC2-T2*-*
[5] Control mode selection
Select the command pulse input method to be used.
[6] Model setting after conversion
Select the motor model used after conversion.
Use the motor same as that before conversion:
Select this when the same motor is used after conversion.
Use the motor different from that before conversion:
Select this when a different motor is used after conversion.
Encoder: Select the encoder after conversion.