EasyManuals Logo

Fuji Xerox DocuPrint M355df User Manual

Fuji Xerox DocuPrint M355df
554 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #385 background imageLoading...
Page #385 background image
Chapter 6 General
6.1 Specifications
6-10
6.1.16 Installation Temperature / Humidity
The temperature and non-condensing relative humidity for installation is as follows:
z At operating: 10-32°C, 10-85%RH (No condensation)
z At standby: minus 20-40°C, 5-85%RH (No condensation)
6.1.17 Installation Altitude
0 to 3,100m
6.1.18 Installation Horizontality
Longitudinal levelness of table surface on which the printer is installed: 1 degree or under
Lateral levelness of table surface on which the printer is installed: 1 degree or under
6.1.19 Storage Temperature of a Toner Cartridge
The guaranteed period of an unpacked print cartridge is as follows:
Normal conditions: 24 months under 0 to 35°C, 15 to 80% RH.
Harsh conditions: 1 month under -20 to 0°C and 35 to 40°C, 5 to 15% RH and 80 to 95% RH.
The storage altitude shall be 0 to 3,500m. Can be extended to 0 to 15,000m when shipped by air.
(Provided that the cargo bay is pressurized to 70.9275Kpa or higher.)
6.1.20 Applicable Laws and Industry Regulations
Table 6-11
Item M/C Specification
Safety Standard
110-127V M/C UL60950-1, CSA 22.2 60950
220-240V M/C IEC60950-1 / EN60950-1
Laser Safety Standard
110-127V M/C FDA21CFR Chapter 1, Subchapter J, Section 1010, 1040
220-240V M/C
IEC60825-1 Amendment 1 + Amendment 2 / EN60825-1
Amendment 1 + Amendment 2 Class 1 Laser Product

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fuji Xerox DocuPrint M355df and is the answer not in the manual?

Fuji Xerox DocuPrint M355df Specifications

General IconGeneral
BrandFuji Xerox
ModelDocuPrint M355df
CategoryPrinter
LanguageEnglish

Related product manuals