Chapter 2 Troubleshooting
2.3 Error Code FIP
2-50
FIP1.6 016-369 UI Panel - ESS Communication Fail
Step Check and Action Yes No
Parts considered to be the cause
CONSOLE ASSY (PL1.1.1)
PWBA ESS (PL18.1.2)
1
Check connector connection
Check the connection between the CONSOLE ASSY
and the PWBA ESS.
Is the CONSOLE ASSY (P/J431) connected
securely?
Go to Step 2.
Securely connect
the CONSOLE
ASSY (P/J431)
2
Check after replacing the CONSOLE ASSY
Replace the CONSOLE ASSY. (REP 1.1)
Does an error occur?
Replace the
PWBA ESS.
(REP18.1)
End of work.