Chapter 6 General
6.10 Parameter Settings (Parameter)
6-68
6.10 Parameter Settings (Parameter)
Use Parameter to read and write the parameters in the IOT.
6.10.1 Registration Settings (Regi)
Displays or changes the registration adjustment values currently set.
Procedure
The following procedure describes how to change the registration values of Fast Scan Smp B Tray (MSI) as
an example.
1 Enter the CE mode. (See "6.4.2 How to Enter the CE Mode".)
2 Confirm that [Printer Diag] is selected, and then press the [OK] button.
3 Use the [T] button to select [Parameter], and then press the [OK] button.
4 Press the [OK] button.
Table 6-43 Registration Parameters
Item Range Description
Regi
Slow Scan K to Paper -15 to +15
Displays or changes the registration adjustment
values of Slow Scan K to Paper.
Fast Scan Smp B Tray
(MSI)
-15 to +15
Displays or changes the registration adjustment
values of Fast Scan Smp B Tray (MSI).
Fast Scan Smp Tray 1
(Standard Tray)
-15 to +15
Displays or changes the registration adjustment
values of Fast Scan Smp Tray 1 (Standard Tray).
Fast Scan Smp Tray 2
(Optional Tray)
-15 to +15
Displays or changes the registration adjustment
values of Fast Scan Smp Tray 2 (Optional Tray).
Fast Scan Dup B Tray (MSI) -15 to +15
Displays or changes the registration adjustment
values of Fast Scan Dup B Tray (MSI).
Fast Scan Dup Tray 1
(Standard Tray)
-15 to +15
Displays or changes the registration adjustment
values of Fast Scan Dup Tray 1 (Standard Tray).
Fast Scan Dup Tray 2
(Optional Tray)
-15 to +15
Displays or changes the registration adjustment
values of Fast Scan Dup Tray 2 (Optional Tray).
Printer Diag
Parameter
Parameter
Regi
Parameter
Regi
Regi
Slow Scan K to Paper