TX2550 M4 Upgrade and Maintenance Manual 121
Basic software procedures
5.2.8 Enabling SVOM boot watchdog functionality
If ServerView Operations Manager boot watchdog functionality has been
disabled for firmware upgrade purposes (see section "Disabling the boot
watchdog functionality of ServerView Operations Manager" on page 106), it has
to be re-enabled to complete the maintenance task.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web interface:
Configuring boot watchdog settings in the BIOS
Ê Enter the BIOS.
Ê Select the Server Mgmt menu.
Ê Under Boot Watchdog set the Action setting to Reset.
Ê Save your changes and exit the BIOS.
I For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
Configuring boot watchdog settings using the iRMC web interface
Ê Log in to the ServerView iRMC web interface.
Ê Select the Settings menu.
Ê Open the Server Management page.
Ê In the Boot Watchdog group, check Enable Boot Watchdog. Select Continue
from the Watchdog Action list.
Ê Click Apply for the changes to take effect.
I For more information on iRMC settings, see the iRMC user guides.
5.2.9 Enabling replaced components in the BIOS
When a CPU, an expansion card, or a memory module fails, the defective
component will be set to Disabled or Failed in the BIOS. The server will then
reboot with only the intact hardware components remaining in the system
configuration. After replacing the defective component, it needs to be re-
enabled in the BIOS.