238 Upgrade and Maintenance Manual TX2550 M4
Hard disk drive (HDD) / solid state drive (SSD)
7.4.10.5 Installing the 8x 3.5-inch HDD front panel
Figure 153: Securing the 8x 3.5-inch HDD front panel
Ê Fit the three hooks on the HDD front panel into the slots in the server front
(see small arrows).
Ê Firmly press down on the HDD front panel until its upper edge is flush with
the chassis (see arrow).
Ê Secure the HDD front panel to the server front with four M3 x 4.5 mm screws
(see circles).
7.4.10.6 Installing the 3.5-inch HDD bay top cover
Ê Install the HDD bay top cover, see section "Installing the 3.5-inch HDD bay
top cover" on page 231.