TX2550 M4 Upgrade and Maintenance Manual 185
Hard disk drive (HDD) / solid state drive (SSD)
7.3.9.1 Preliminary steps
Ê "Locating the defective server" on page 49
Ê When working on a floorstand model, open the HDD bay cover, see section
"Removing the drive covers" on page 64.
Ê "Locating the defective component" on page 51
7.3.9.2 Removing a 2.5-inch HDD/SSD module
Ê Remove the HDD/SSD module to be replaced from the server, see section
"Removing a 2.5-inch HDD/SSD module" on page 183.
Ê If applicable, remove the HDD/SSD from the installation frame, see section
"Handling HDDs or SSDs without installation frame" on page 160.
7.3.9.3 Installing a 2.5-inch HDD/SSD module
Ê If applicable, install the HDD/SSD in the installation frame, see section
"Handling HDDs or SSDs without installation frame" on page 160.
Ê Install the new HDD/SSD module into the empty drive bay, see section
"Installing 2.5-inch HDD/SSD modules" on page 179.
7.3.9.4 Concluding steps
Ê When working on a floorstand model, close the HDD bay cover, see section
"Installing the drive covers" on page 76.
Ê "Performing a RAID array rebuild" on page 128
7.3.10 Replacing a 2.5-inch HDD SAS backplane
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver