TX2550 M4 Upgrade and Maintenance Manual 181
Hard disk drive (HDD) / solid state drive (SSD)
Figure 100: Installing the 2.5-inch HDD/SSD module
Ê Insert the HDD/SSD module into a drive bay and carefully push back as far
as it will go (1).
Ê Close the locking lever to lock the HDD in place (2).
Ê When using a RAID array, add the additional HDD/SSD to the RAID array.
I Configuring the RAID array, refer to the documentation of the RAID
controller, used in your configuration, see section "Documents you
need at hand" on page 33.
7.3.7.4 Concluding steps
Ê When working on a floorstand model, close the HDD bay cover, see section
"Installing the drive covers" on page 76.
7.3.8 Removing 2.5-inch HDD/SSD modules
I PCIe SSDs SFF are mounted in the same frames as the 2.5-inch
HDD/SSD modules. Therefore, this section is also valid and applicable if
PCIe SSDs SFF are used.
The preliminary and concluding steps are only necessary for HDD/SSD
modules, not for the PCIe SSDs SFF. PCIe SSDs SFF are never
combined in a RAID array.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools: tool-less