EasyManua.ls Logo

Fujitsu PRIMERGY TX2550 M4 - Removing a 2.5-Inch HDD;SSD Module; Installing a 2.5-Inch HDD;SSD Dummy Module; Concluding Steps

Fujitsu PRIMERGY TX2550 M4
563 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TX2550 M4 Upgrade and Maintenance Manual 183
Hard disk drive (HDD) / solid state drive (SSD)
7.3.8.2 Removing a 2.5-inch HDD/SSD module
Ê Pinch the green locking clips and open the locking lever (see figure 99).
Ê Pull the HDD/SSD module out a few centimeters.
Ê Wait about 30 seconds to allow the HDD to spin down.
I This is not necessary when removing an SSD.
I This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
Ê Pull the HDD/SSD module completely out of its bay.
7.3.8.3 Installing a 2.5-inch HDD/SSD dummy module
V CAUTION!
If the removed HDD/SSD module is not replaced immediately, always
replace a dummy module into the unused HDD/SSD bay to comply with
applicable EMC regulations and satisfy cooling requirements.
Figure 101: Installing a 2.5-inch HDD/SSD dummy module
Ê Push the dummy module into the empty bay until it engages.
7.3.8.4 Concluding steps
Ê When working on a floorstand model, close the HDD bay cover, see section
"Installing the drive covers" on page 76.

Table of Contents

Other manuals for Fujitsu PRIMERGY TX2550 M4

Related product manuals