TX2550 M4 Upgrade and Maintenance Manual 403
12.6.3 Replacing the ultraslim ODD
12.6.3.1 Preliminary steps
Ê "Locating the defective server" on page 49
Ê "Removing backup and optical disk media" on page 108
Ê "Shutting down the server" on page 52
Ê "Disconnecting the power cord" on page 53
Ê "Getting access to the component" on page 54
I Removing the front cover is not required in order to replace the
ultraslim ODD.
Ê "Removing the system air duct" on page 67
Ê If applicable, "Removing the riser module" on page 84
Ê If applicable, remove the expansion card, see section "Removing an
expansion card" on page 318.
Ê Remove the fan bridge, see section "Handling fan bridges" on page 90.
Ê If applicable, "Removing the 4x 3.5-inch HDD extension box" on page 255
12.6.3.2 Removing the defective ultraslim ODD
Ê Remove the ultraslim ODD adapter, see section "Removing an accessible
drive" on page 386.
Ê Remove the ultraslim ODD, see section "Removing the ultraslim ODD from
the ultraslim ODD adapter" on page 401.
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tools: – Phillips PH0 / (+) No. 0 screw driver
– Slotted screw driver (for bending in or out accessible drive
mounting brackets)