Fujitsu PRIMERGY TX2550 M4 - Preliminary Steps; Removing the 2.5-Inch HDD Bay Top Cover

Fujitsu PRIMERGY TX2550 M4
563 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
186 Upgrade and Maintenance Manual TX2550 M4
Hard disk drive (HDD) / solid state drive (SSD)
7.3.10.1 Preliminary steps
Ê "Locating the defective server" on page 49
Ê "Shutting down the server" on page 52
Ê "Disconnecting the power cord" on page 53
Ê "Getting access to the component" on page 54
Ê Remove all HDD/SSD modules, see section "Removing 2.5-inch HDD/SSD
modules" on page 181.
Ê "Removing the system air duct" on page 67
Ê Remove the fan bridge, see section "Handling fan bridges" on page 90.
Ê Disconnect all cables from the defective SAS backplane.
7.3.10.2 Removing the 2.5-inch HDD bay top cover
I The 2.5-inch HDD front panel does not need to be removed in order to
replace a 2.5-inch HDD SAS backplane. In the figures, the front panel
has been removed for illustration purposes only.
Figure 102: Removing the intrusion switch holder (A)
Ê Remove one screw from the intrusion switch holder as shown.