162 Standby Operation Description
To cancel the remote standby duration timer, touch the Start or Stop buttons.
---- X:XX:XX X:XX:XX Trigger Yes System delays for a specified time and
then enters Standby until the timer
completes. If the input signal changes
state while the delay timer is active,
the delay timer is reset to the specified
value.
---- X:XX:XX 0:00:00 Trigger Yes System delays for specified time and
then enters Standby indefinitely. If the
input signal changes state while the
delay timer is active, the delay timer is
reset to the specified value.
---- 0:00:00 0:00:00 ON/OFF ---- System enters Standby until the input
signal is not active.
---- 0:00:00 X:XX:XX ON/OFF ---- System enters Standby until the input
signal is not active or the timer
completes.
---- X:XX:XX X:XX:XX ON/OFF ---- System delays for a specified time and
then enters Standby until the signal is
not active or the timer completes.
---- X:XX:XX 0:00:00 ON/OFF ---- System delays for a specified time and
then enters Standby until the input
signal is not active.
---- ---- ---- Direct ---- System enters Standby until the input
signal is not active. If the input signal is
active when the system is started, it
will immediately go into Standby
mode.
Table 10-16 Remote Standby Operational Description (Continued)
Manual
Time
Delay
Time
Remote
Time
Input
Mode
Cycle
Enabled
Operation - STANDBY Button Select