v 2.0 — March 2023 Altanium Delta5
82 Change the Manual Standby Setpoint Limits
7.8.8.2.1 Change the Manual Standby Setpoint Limits
To change a Manual Standby setpoint and limits for a zone, do the steps that follow:
1. Touch the zone to be changed on the Quick Set screen.
2. Touch the Manual Standby drop-down tab.
3. Touch the Temperature Setpoint field and enter a temperature value.
4. Touch the Accept button.
5. Touch the Temperature Minimum field and enter a temperature value.
6. Touch the Accept button.
7. Touch the Temperature Maximum field and enter a temperature value.
8. Touch the Accept button.
9. Touch the Power Setpoint field and enter a percentage value.
10. Touch the Accept button.
11. Touch the Power Minimum field and enter a percentage value.
12. Touch the Accept button.
13. Touch the Power Maximum field and enter a setpoint percentage value.
14. Touch the Accept button.
7.8.8.2.2 Change the Remote Standby Setpoint Limits
To change a Remote Standby setpoint and limits for a zone, do the steps that follow:
1. Touch the zone to be changed on the Quick Set screen.
2. Touch the Remote Standby drop-down tab.
3. Touch the Temperature Setpoint field and enter a temperature value.
4. Touch the Accept button.
5. Touch the Temperature Minimum field and enter a temperature value.
6. Touch the Accept button.
7. Touch the Temperature Maximum field and enter a temperature value.
8. Touch the Accept button.
9. Touch the Power Setpoint field and enter a percentage value.
10. Touch the Accept button.
11. Touch the Power Minimum field and enter a percentage value.
12. Touch the Accept button.
13. Touch the Power Maximum field and enter a setpoint percentage value.
14. Touch the Accept button.
7.8.8.3 Change the Manual Boost Setpoints and Limits
There could be a condition when it is necessary to increase the temperatures in the mold for
a period of time. This is done under the Manual Boost drop-down tab (or Remote Boost from
a remote location as an option), so it is not necessary to change the operation temperature