v 2.0 — March 2023 Altanium Delta5
72 Setpoint Limits
7.8.1.3 Setpoint Limits
The Setpoint Limits fields are described in Table 7-9.
7.8.1.4 Manual Standby
The Manual Standby fields are described in Table 7-10.
Table 7-9 Setpoint Limits Fields
Item Description
Temperature Minimum
These values are the range limits in which the Temperature Setpoint field
can be set.
Temperature Maximum
Power Minimum
These values are the percentage range limits in which the Power Setpoint
field can be set.
Power Maximum
Table 7-10 Manual Standby Fields
Item Description
Temperature Setpoint The temperature to which all zones are set when the Standby button is
touched. This setting can be used to lower all zone temperatures to their
Manual Standby temperature setpoint until the timer completes or the
user touches the Standby button again. Possible values are 0 to 500 °C or
32 to 932 °F. The default value is 121 °C or 250 °F.
Temperature Minimum
These values specify the range limits in which the Standby temperature
can be set.
Temperature Maximum
Power Setpoint The power output to which all zones are set when the Standby button is
touched. This setting can be used to lower all zone power setpoints to
their Manual Standby power setpoint until the timer completes or the
user touches the Standby button again. Possible values are 0% – 100%.
The default value is 10%.
Power Minimum
These values specify the percentage range limits in which the Standby
power can be set.
Power Maximum