Set the Remote Standby Input Mode 161
User Guide v 2.0 — March 2023 System Setup
10.19.4 Set the Remote Standby Input Mode
The Remote Standby Input Mode setting is enabled by one of three settings: Trigger, On/Off,
or Direct.
NOTE: This setting does not show if the remote standby option is not installed on the system.
To change the Remote Standby Input mode, do the steps that follow:
1. On the System Setup screen, touch the Heats Setup tab and then touch the Control
Page 1 tab.
2. Touch the Remote Standby Input Mode field that is below Remote Standby.
3. Touch mode in the list to select it.
10.19.5 Standby Operation Description
The settings for manual and remote standby operations are described in Table 10-15 and
Table 10-16.
If it is necessary to cancel the manual standby duration timer, touch the Start or Stop
buttons.
Table 10-15 Manual Standby Operational Description
Manual
Time
Delay
Time
Remote
Time
Input
Mode
Cycle
Enabled
Operation - STANDBY Button Select
0:00:00 ---- ---- ---- ---- System enters Standby indefinitely.
X:XX:XX ---- ---- ---- ---- System remains in Standby until the
timer completes.
Table 10-16 Remote Standby Operational Description
Manual
Time
Delay
Time
Remote
Time
Input
Mode
Cycle
Enabled
Operation - STANDBY Button Select
---- 0:00:00 0:00:00 Trigger ---- System does not enter Standby,
because no timers are set.
---- 0:00:00 X:XX:XX Trigger ---- System immediately enters and
remains in Standby until the timer
completes.
---- X:XX:XX X:XX:XX Trigger No System delays for a specified time and
then enters Standby until the timer
completes.
---- X:XX:XX 0:00:00 Trigger No System delays for specified time and
then enters Standby indefinitely.