Change the Remote Boost Setpoints and Limits 83
User Guide v 2.0 — March 2023 Making Adjustments
setpoint. Set the temperatures to heat the heaters in the mold to when the system is in Boost.
The default setpoint is No Chg (No Change). The No Change setpoint tells the system to make
no changes to the heaters during Manual or Remote Boost.
To change a Manual Boost setpoint and limits for a zone, do the steps that follow:
1. Touch the zone to be changed.
2. Touch the Manual Boost drop-down tab.
3. Touch the Temperature Setpoint field and enter a temperature value.
4. Touch the Accept button.
5. Touch the Temperature Minimum field and enter a temperature value.
6. Touch the Accept button.
7. Touch the Temperature Maximum field and enter a temperature value.
8. Touch the Accept button.
9. Touch the Power Setpoint field and enter a percentage value.
10. Touch the Accept button.
11. Touch the Power Minimum field and enter a percentage value.
12. Touch the Accept button.
13. Touch the Power Maximum field and enter a setpoint percentage value.
14. Touch the Accept button.
7.8.8.4 Change the Remote Boost Setpoints and Limits
To change a Remote Boost setpoint and limits for a zone, do the steps that follow:
1. Touch the zone to be changed.
2. Touch the Remote Boost drop-down tab.
3. Touch the Temperature Setpoint field and enter a temperature value.
4. Touch the Accept button.
5. Touch the Temperature Minimum field and enter a temperature value.
6. Touch the Accept button.
7. Touch the Temperature Maximum field and enter a temperature value.
8. Touch the Accept button.
9. Touch the Power Setpoint field and enter a percentage value.
10. Touch the Accept button.
11. Touch the Power Minimum field and enter a percentage value.
12. Touch the Accept button.
13. Touch the Power Maximum field and enter a percentage value.
14. Touch the Accept button.