v 2.0 — March 2023 Altanium Delta5
276 Replace an Open Fuse on an Intelligent Control Card
16.3.2 Replace an Open Fuse on an Intelligent Control Card
To replace an open fuse, do the steps that follow:
1. Find the Card Cage that contains the ICC
2
or ICC
3
that has the fault. Refer to number 1 in
Figure 16-10.
NOTE: You can use the on-screen Card Layout feature to help in find the card.
2. De-energize the system at the Altanium main power switch. Refer to Figure 16-2.
3. Lock out and tag the main power switch in accordance with local codes.
4. Loosen the upper and lower slotted fasteners on the heat sink from the female threads
in the cabinet. Refer to number 2 in Figure 16-10.
5. Slide a screwdriver between the silver post and the ledge on the cabinet and gently pry
the board out. Refer to number 3 in Figure 16-10.
6. Carefully put the card on an earthed/grounded surface.
WARNING!
Electrical and mechanical hazard- risk of death, serious injury and/or damage to the
equipment. Turn off all power to the system and disconnect it completely from the
main input power.
CAUTION!
Mechanical failure mode - attempting to remove a card when the upper and lower
heatsink mounting screws are not fully disengaged from the female threads on the
cabinet can result in catastrophic damage to the card.
CAUTION!
The ICC
2
an ICC
3
cards are electrostatic discharge sensitive. Use a ground strap when
handling Altanium components.
CAUTION!
Static electricity hazard – risk of damage to the equipment. A static charge could
damage a PCB. Do not place any PCB on carpets, rugs, or other material that is likely to
create a static charge.