v 2.0 — March 2023 Altanium Delta5
196 Global Settings
7. If you want to set these Target Settings critical, touch the Critical field and select Yes.
8. If you want to activate the Process Outside Limit (Digital Output 6) signal during an out
of limit condition, touch the Process Outside Limits checkbox, so the check mark
shows.
12.3.2 Global Settings
In the Global Settings panel, you can set a Critical Variable Action for the heats and/or servos
that are installed on your system. For heats, the selections are No Reaction or Stop Heats. For
servos, the selections are No Reaction or Stop End of Cycle.
To set a Critical Variable Action, do the steps that follow:
1. On the process Limits screen, touch the Heats or Servos field.
2. Select the action you want for the heats or servos.
12.3.3 Delay Limit Check
If you want the Altanium controller to wait a specified time or number of cycles before the
system does the limit check, those parameters can be set in the Delay Limit Check panel.
To set the heats parameter, do the steps that follow:
1. On the process Limits screen, touch the Heats Time Delay Limit field and enter the
number of seconds for the delay (1 to 900 seconds).
2. Touch the Accept button.
To set the servos parameter, do the steps that follow:
1. On the process Limits screen, touch the Servo Cycle Delay field and enter the number
of cycles for the delay (1 to 999 cycles).
2. Touch the Accept button.
12.3.4 Process Variable Selector
If you want to filter what you see listed on the process Limits screen, you can use the Process
Variable Selector. This lets you select one or more zone groups, Process Monitoring, and/or
servos (such as UltraSync-E).
To filter what is shown on the process Limits screen, do the following:
1. On the process Limits screen, touch the Process Variable Selector button.
The Process Variable Selector dialog window shows. Refer to Figure 12-8.