164 Change the Remote Boost Input Mode
3. Enter the time requirement in this format: HHMMSS.
4. Touch the Accept button.
10.20.4 Change the Remote Boost Input Mode
The Remote Boost Input Mode setting is enabled by one of three settings: Trigger, On/Off, or
Direct.
NOTE: If remote boost is not installed on the system, the Remote Boost Input Mode field will
not show on the screen.
To change the Remote Boost Input Mode, do the steps that follow:
1. On the System Setup screen, touch the Heats Setup tab and then touch the Control
Page 1 tab.
2. Touch the Remote Boost Input Mode field that is below Remote Boost.
3. Touch mode in the list to select it.
10.20.5 Boost Operation Description
The settings for manual and remote boost operations are described in Table 10-17 and
Table 10-18.
If it is necessary to cancel Manual Boost, touch the Start or Stop buttons.
Table 10-17 Manual Boost Operational Description
Manual
Time
Delay
Time
Remote
Time
Input
Mode
Cycle
Enabled
Operation - BOOST Button Select
0:00:00 ---- ---- ---- ---- System enters Boost indefinitely.
X:XX:XX ---- ---- ---- ---- System remains in Boost until the
timer completes.
Table 10-18 Remote Boost Operational Description
Manual
Time
Delay
Time
Remote
Time
Input
Mode
Operation - Boost Button Select
---- 0:00:00 0:00:00 Trigger System will not enter Boost because no timers are
set.
---- 0:00:00 X:XX:XX Trigger System immediately enters and remains in Boost
until the timer completes.
---- X:XX:XX X:XX:XX Trigger System delays for specified time and then enters
Boost until the timer completes.
---- X:XX:XX 0:00:00 Trigger System delays for specified time and then enters
Boost indefinitely.