User Guide v 2.0 — March 2023 System Options
Digital I/O 243
Chapter 14 System Options
The Altanium controller has many additional optional features available to help in the
molding process. There are hardware, software, and a combination of hardware and software
options that can be used to maximize the system.
14.1 Digital I/O
Use the I/O screen to configure the digital inputs and outputs. On the Home screen, touch
the I/O button.
The I/O options are divided into four categories:
• Safety
• Digital Inputs
• Digital Outputs
• Configurable Signals
The tabs at the bottom of the screen are used to access each I/O category. Table 14-1 gives a
list of items found on the I/O screens with their descriptions.
To configure the I/O, select a tab for safety, inputs, outputs, or configurable signals to see the
I/O you want. If your Altanium controller has heats and/or servos installed, the digital inputs
and outputs screens will show sub-tabs related to those features. Navigate to the I/O and
configure the settings as necessary to the requirements.
Table 14-1 Digital I/O Screen Item Descriptions
Item Description
Name The name of the input and output option.
Function A description of the input or output option.
Active Indicates if the feature is active (green) or inactive (grey).
Invert Used to manually invert the I/O condition that it is in at this time.
In Use Used to set the I/O heats options On or Off.
Level Indicates (green) if there is a signal at the physical hardware pins.
Schematic Relates to the input or output number assigned to the option.
Pins The connector pins related to each input and output.