Setpoint Limits 81
User Guide v 2.0 — March 2023 Making Adjustments
To change the zone regulation, do the step that follow:
1. On the Quick Set screen, touch the zone to be changed.
2. Touch the Frequently Used drop-down tab.
3. Touch the Regulation Mode field.
A Regulation Mode dialog window shows with the three mode choices.
4. Touch a mode to select it, or touch the Exit icon to cancel the operation.
7.8.8 Setpoint Limits
The Altanium system lets you set temperature and power ranges in which operators cannot
make changes to the setpoints that are greater than or less than the specified range limits.
7.8.8.1 Change the Normal Setpoint and Limits
On the Quick Set screen, under the Frequently Used drop-down tab, enter the temperature
to heat the heaters in the mold. The default temperature is 177 °C (350 °F).
To change the operation setpoint and limits for a zone, do the steps that follow:
1. Touch the zone to change.
2. Touch the Setpoint Limits drop-down tab.
3. Touch the Temperature Minimum field and enter a temperature value.
4. Touch the Accept button.
5. Touch the Temperature Maximum field and enter a temperature value.
6. Touch the Accept button.
7. Touch the Power Minimum field and enter a percentage value.
8. Touch the Accept button.
9. Touch the Power Maximum field and enter a percentage value.
10. Touch the Accept button.
7.8.8.2 Change the Manual Standby and Remote Standby Setpoint Limits
There could be a condition when it is necessary to decrease the temperatures in the mold for
a period of time. This is done under the Manual Standby drop-down tab (or Remote Standby
drop-down tab from a remote location as an option), so it is not necessary to change the
operation temperature setpoint. Set the temperatures for the heaters in the mold to cool
down to when the system is in Standby (Manual and Remote). The default temperature for
both the manual and remote standby setpoints is 121 °C (250 °F).
CAUTION!
If a zone is changed to Monitor mode, the system will not apply power output to that
heater.