v 2.0 — March 2023 Altanium Delta5
42 Screen Security - Heats Page 1 Screen
Part Counting Setup Select the user role that can use the Part Counting Setup function on the
Heats Setup tab of the System Setup screen.
Temperature
Calibration
Select the user role that can use the parameters in the Calibration screen to
calibrate temperatures.
No Heater Detected
Enable
Select the user role that can enable or disable no-heater detection feature
in the Heats Setup of the System Setup screen.
Thermocouple
Reading
Select the user role that can select and clear the Display Thermocouple
Reading for Manual Zones checkbox on the System Setup screen.
Power Deviation Select the user role that can select the Setup Alarm button in the Power
Deviation section on the System Setup screen.
Zone Slot
Configuration
Select the user role that can operate the Zone Slot Configuration fields on
the System Setup screen and the fields on the Zone Slot Configuration
screen.
Zone Alarm Control
Settings
Select the user role that can configure all the parameters in the Zone Alarm
Control panel of the System Setup screen.
Mold Cooling Enable
Limit
Select the user role that can change this parameter in the Mold Cooling
Enable panel of the System Setup screen.
Remote Load Setup Select the user role that can configure all the parameters in the Remote
Load Setup dialog window. This option must be purchased before the user
can access this dialog window.
SPI Select the user role that can configure parameters in the SPI panel of the
System Setup screen. SPI must be installed on the system.
Resin Protection
Timer
Select the user role that can set the protect resin timer on the Heats Setup
screen in the System Setup.
Color Change Select the user role that can set the parameters for the color change screen.
Soft Start Enable Select the user role that can enable or disable Soft Start on the Heats Setup
tab of the System Setup screen.
Soft Start Setup Select the user role that can set the Soft Start Minimum Limit temperature
on the Heats Setup tab of System Setup screen.
Earth Leakage Fault
Enable
Select the user role that can enable and disable the System Earth Leakage
Enable checkbox on the Heats Setup tab of the System Setup screen.
Earth Leakage Fault
Setup
Select the user role that can operate the fields that follow on the System
Setup screen:
Earth Leakage Fault Enable checkbox
Earth Leakage Limit field
Display Earth Leakage Reading checkbox
Circuit Overload Enable checkbox
Circuit Test Enable checkbox
Table 5-5 Screen Security - Heats Page 1 Screen (Continued)
Item Description