Chapter 5 List of Parameters 5.7 Other Parameters
201
Other Parameters
No. Parameter name
Default
value
(Reference)
Input range Unit Remarks
46
Other setting bit
pattern 1
Common 2001H
0H ~
FFFFFFFFH
Bits 0 to 3: System reservation (Change prohibited)
Bits 4 to 7: When substituting integer variable in LET / TRAN
Command real number, selection of round-off of
decimal fraction
(0: Not to round off, 1: Round off)
Bits 8 to 11: System reservation
Bits 12 to 15: When indicating TPCD Command = 1, Selection of
process of Sub-routine 1
st
Step Input Condition
Unindicated Command
(0: Not executed, 1: Executed, 2: Error)
Bits 16 to 19: Selection of CHVL command speed valid period
type
(0: Valid only for the main packet currently
operating,
1: Valid during continuous packet handling)
* If 1, the speed specified by the CHVL command
is retained during PATH and other continuous
movement commands (must be input to
continuous program steps).
However, the following limitations apply:
The speed specified by the CHVL command is
clamped, on the upper limit side, at the actual
speed during the command operation before the
change.
If the timing at which the CHVL command is
executed on a continuous movement command
overlaps with the connection of each position
movement packet, two-step speed changes may
occur until the specified speed is reached.
The connection speed for each position
movement packet may increase in proportion to
the deceleration.
(Example. 9.8 mm/sec at 1.0 G, 4.9 mm/sec at 0.5
G)
For items not specified above, refer to the notes
provided in the CHVL command section of the
operation manual.
47
Other setting bit
pattern 2
Common 1H
0H ~
FFFFFFFFH
Bits 0 to 3: Calendar function use selection
(0: Not in use, 1: Use, 2: Not in use (Use the elapsed
time after the reset))
* Clear all data in error list when making change
Bits 4 to 7: 7-segment display factor switchover
(0: Valid, 1: Invalid)
* Display is switched among Emergency stop /
ENB / Cold-start, Operation cancel level error.
Bits 8 to 11: Use servo monitor IO monitoring function
(0: Not in use, 1: Use)
Bits 12 to 15: Classification of seven-segment display for program
in execution
(0: Displays program number started up at last
1: Displays program number started up at the
earliest
Bits 16 to 19: PARG acquirement angle coordinate direction
select
(0: CW
1: CCW)
(Main application part V2.00 or later)
Bits 20 to 31: For future extension
48 (For extension) Common 0
49 (For extension) Common 0
50 (For extension) Common 0
51 (For extension) Common 0
52 (For extension) Common 0
Pulse
Motor Type
3H
0H ~
FFFFFFFFH
Bit 0 : Monitoring status of Fan 1
(0: Invalid, 1: Valid)
Bit 1: Monitoring status of Fan 2
(0: Invalid, 1: Valid)
Bits 2 to 31: System reservation
53
Fan status monitoring
setting 1
AC Servo
Motor Type
3H
0H ~
FFFFFFFFH
Bit 0 : Monitoring status of Fan 1
(0: Invalid, 1: Valid)
Bit 1: Monitoring status of Fan 2
(0: Invalid, 1: Valid)
Bit 2: Monitoring status of Fan 3
(0: Invalid, 1: Valid)
Bit 3: Monitoring status of Fan 4
(0: Invalid, 1: Valid)
Bits 4 to 31: System reservation