Chapter 6 Error List6.2 Error List (MAIN Application)
214
Error No. Error name Description, action, etc.
803 Receive timeout status (IAI protocol reception)
The transfer interval after the first received byte is too long. Possible causes include disconnected
communication cable and error in the connected equipment.
804 SCIF overrun status (SEL reception) Communication failure. Check for noise, connected equipment and communication setting.
805 SCIF receive ER status (SEL reception)
Communication failure. Check for noise, shorted/disconnected communication cable, connected
equipment and communication setting.
806
SCIF receive ER status due to other factor (SEL
reception)
Communication failure. Take the same action specified for error No. 804 or 805.
807 Drive-source cutoff relay ER status
The motor-drive power ON status remains ON even when the drive source is cut off. The
drive-source cut-off relay contacts may have been melted.
808 Power OFF status during slave parameter write The power was turned off while writing slave parameters.
809 Power OFF status during data write to flash ROM The power was turned off while writing data to the flash ROM.
80A Extension SIO overrun status (at SEL receiving)
[Detail & Cause]
The overrun error was detected while receiving extension SIO.
[Countermeasure]
Contact IAI if this occurs even after rebooting power.
80B Extension SIO parity ER status (at SEL receiving)
[Detail & Cause]
The parity error was detected while receiving extension SIO.
[Countermeasure]
Check the noise prevention measures and communication settings on both receiving and sending
devices.
80C Extension SIO framing ER status (at SEL receiving)
[Detail & Cause]
The framing error was detected while receiving extension SIO.
[Countermeasure]
Check the noise prevention measures and communication settings on both receiving and sending
devices.
80D
Extension SIO other factor receiving ER status (at SEL
receiving)
[Detail & Cause]
An error other than Error No. 80A, 80B and 80C was detected while receiving extension SIO.
[Countermeasure]
Contact IAI if this occurs even after rebooting power.
80E
Extension SIO receiving buffer overflow status (at SEL
receiving)
[Detail & Cause]
The extension SIO receiving buffer has overflown. Excessive amount of data is being received
from external devices.
[Countermeasure]
Check the sent data from connected devices and delimiter setting in SEL program.
80F Ethernet control status 1 Ethernet control information (For analysis)
810 Ethernet control status 2 Ethernet control information (For analysis)
811 Maintenance information 1 Maintenance information (For analysis)
812 Maintenance information 2 Maintenance information (For analysis)
813 Maintenance information 3 Maintenance information (For analysis)