To view system information using SCPI commands:
To retrieve the manufacturer, model number, serial number, and firmware version, send the
command:
*IDN?
To read the line frequency, send the command:
SYStem:LFRequency?
The firmware build, memory available, and factory calibration date are not available when using SCPI
commands.
To get information about how many times autocalibration has been done, autocalibration
temperature, and last autocalibration dates, send the following commands:
:ACAL:COUNt?
:ACAL:LASTrun:TEMPerature:INTernal?
:ACAL:LASTrun:TEMPerature:DIFFerence?
:ACAL:LASTrun:TIME?
To view system information using TSP commands:
To read the model number, send the command:
print(localnode.model)
To read the serial number, send the command:
print(localnode.serialno)
To read the firmware version, send the command:
print(localnode.version)
To read the line frequency, send the command
print(localnode.linefreq)
To get information about how many times autocalibration has been done, autocalibration
temperature, and last autocalibration dates, send the following commands:
print(acal.count)
print(acal.lastrun.internaltemp)
print(acal.lastrun.tempdiff)
print(acal.lastrun.time)
The factory calibration date is not available with TSP commands.
You can also create user-defined strings to store custom, instrument-specific information in the
instrument, such as department number, asset number, or manufacturing plant location. See the TSP
command reference (on page 8-1) for detail about the userstring functions.

Table of Contents

Other manuals for Keithley 2461

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2461 and is the answer not in the manual?

Keithley 2461 Specifications

General IconGeneral
Maximum Current7 A
Power100 W
Resolution6.5 digits
Source Measure Unit (SMU)Yes
DC Voltage100 V
Maximum Voltage100 V
Display5-inch capacitive touchscreen
ConnectivityUSB, GPIB
SoftwareTSP
DC Current7 A
Current Source Range0 to 7 A
Voltage Measurement Range100 mV to 100 V
Current Measurement Range10 nA to 7 A
Voltage Measurement Resolution100 nV

Related product manuals