6: SCPI command reference Model 2461 Interactive SourceMeter® Instrument
Reference Manual
6-76 2461-901-01 A/November 2015
Details
This command recalls data for one configuration index from the specified measure configuration list
and from the source configuration list (if specified).
For additional information about the information this command recalls when using a configuration list
query command, see Instrument settings stored in a measure configuration list (on page 3-33).
Example
:SENS:CONF:LIST:QUER? "MyMeasList", 2, 3
Returns the TSP commands and parameter settings that represent the settings in
configuration index 2.
Also see
Configuration lists (on page 3-30)
[:SENSe[1]]:CONFiguration:LIST:CREate (on page 6-74)
TSP command reference (on page 8-1)
[:SENSe[1]]:CONFiguration:LIST:RECall
This command recalls a configuration index in a measure configuration list and an optional source configuration
list.
Type Affected by Where saved Default value
Command only
Not applicable
Not applicable
Not applicable
Usage
[:SENSe[1]]:CONFiguration:LIST:RECall "<name>"
[:SENSe[1]]:CONFiguration:LIST:RECall "<name>", <index>
[:SENSe[1]]:CONFiguration:LIST:RECall "<name>", <index>, "<sourceName>"
[:SENSe[1]]:CONFiguration:LIST:RECall "<name>", <index>, "<sourceName>",
<sourceIndex>
<name>
A string that represents the name of a measure configuration list
<index>
A number that defines a specific configuration index in the measure
configuration list
<sourceName>
A string that represents the name of a source configuration list
<sourceIndex>
A number that defines a specific configuration index in the source
configuration list

Table of Contents

Other manuals for Keithley 2461

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2461 and is the answer not in the manual?

Keithley 2461 Specifications

General IconGeneral
Maximum Current7 A
Power100 W
Resolution6.5 digits
Source Measure Unit (SMU)Yes
DC Voltage100 V
Maximum Voltage100 V
Display5-inch capacitive touchscreen
ConnectivityUSB, GPIB
SoftwareTSP
DC Current7 A
Current Source Range0 to 7 A
Voltage Measurement Range100 mV to 100 V
Current Measurement Range10 nA to 7 A
Voltage Measurement Resolution100 nV

Related product manuals