Model 2461 Interactive SourceMeter® Instrument
Reference Manual
2 2461-901-01 A/November 2015
effects on scripts • 2-143
event blenders • 3-104
event log • 2-141
examples
digital I/O programming • 3-95
interactive triggering • 3-105
extended warranty • 1-1
F
FAQs • 9-1
filter, digital
repeating average • 4-23
filters • 4-23
firmware upgrade • A-3
front panel
display • A-2
functions • 7-1
Lua • 7-17
G
ghost image, removing • A-2
GPIB • 2-57
setup • 2-57
gpib attribute
gpib.address • 8-82
graphing • 2-130
groups, TSP-Link
assigning • 3-157
coordinating overlapped operations • 3-158
leader • 3-157
manage nodes • 3-156
I
Info/Manage menu • 2-45
instrument access • 3-77
interactive script
interactive triggering • 3-105
internal temperature • 3-53
K
Keithley I/O layer • 2-78
L
LAN
setup • 2-61
triggering • 3-100
libraries, standard • 7-25
limit test • 3-134
line
fuse replacement • A-1
log event • 3-114
loop control • 7-20
loop counter building block • 3-117
low current measurements, improve
Digitize block • 3-110
Lua • 7-11, 7-12
reference • 7-12
LXI • 2-74
M
maintenance • A-1
master
node, TSP-Link • 3-156
math
library functions • 7-28
Measure building block • 3-108
Measure Calculations menu • 2-28
Measure Config Lists menu • 2-30
Measure Reading Buffers menu • 2-30
measurement
continuous • 3-98
voltage • 3-98, 3-99
mounting • 2-52
moving average filter • 4-23
multiple instruments, connecting
TSP-Link • 3-150
mX+b • 3-79, 3-82, 3-84, 8-163
N
node
master overview • 3-156
TSP-Link • 3-152, 3-157
nonvolatile memory • 7-5
notify block • 3-112, 3-133
O
offset, relative • 3-79, 3-80, 3-81, 6-71, 6-73, 6-74, 8-
172, 8-173, 8-174
on event building block • 3-118
once building block • 3-121
once excluded building block • 3-121
operations
mX+b • 3-79, 3-82, 3-84, 8-163
reciprocal (1/X) • 3-83, 3-85, 6-20, 8-122, 8-163
operator precedence • 7-17
operators (Lua) • 7-14
overlapped operations • 3-158
overlapped operations in remote groups,
coordinating • 3-158
P
password • 2-77
percent • 2-28, 3-83, 3-84, 8-125
performance slider • 2-101
power on script • 7-10
programming • 7-3, 7
-11,
See command
interaction • 7-32

Table of Contents

Other manuals for Keithley 2461

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2461 and is the answer not in the manual?

Keithley 2461 Specifications

General IconGeneral
Maximum Current7 A
Power100 W
Resolution6.5 digits
Source Measure Unit (SMU)Yes
DC Voltage100 V
Maximum Voltage100 V
Display5-inch capacitive touchscreen
ConnectivityUSB, GPIB
SoftwareTSP
DC Current7 A
Current Source Range0 to 7 A
Voltage Measurement Range100 mV to 100 V
Current Measurement Range10 nA to 7 A
Voltage Measurement Resolution100 nV