2WA/2NJ/2RK
7-492
F4AX,
F4CX
Abnormality detecting of a printer rendering
part
(1) Initialize HDD and perform an operation check.
(FULL of U024) *
(2) U021 Main backup initialization is carried out and an operation
check is performed.
(3) Exchange Main PWB, and perform an operation check.
(4) Exchange HDD, and perform an operation check. *
(5) Get USBLOG and contact to service headquarters.
* : Only HDD standard model
F4DX,
0
Abnormality detecting in the Entity Manage-
ment Department
(1) Initialize HDD and perform an operation check.
(FULL of U024) *
(2) U021 Main backup initialization is carried out and an operation
check is performed.
(3) Exchange Main PWB, and perform an operation check.
(4) Exchange HDD, and perform an operation check. *
(5) Get USBLOG and contact to service headquarters.
* : Only HDD standard model
F4FX Abnormality detecting in the JOB Management
Department
(1) Initialize HDD and perform an operation check.
(FULL of U024) *
(2) U021 Main backup initialization is carried out and an operation
check is performed.
(3) Exchange Main PWB, and perform an operation check.
(4) Exchange HDD, and perform an operation check. *
(5) Get USBLOG and contact to service headquarters.
* : Only HDD standard model
Since the USB log immediately after
occurrence is needed for analysis,
please give me cooperation of the
acquisition.
F50X Abnormality detecting in the FAX Management
Department
(1) Initialize HDD and perform an operation check.
(FULL of U024) *
(2) U021 Main backup initialization is carried out and an operation
check is performed.
(3) Exchange Main PWB, and perform an operation check.
(4) Exchange HDD, and perform an operation check. *
(5) Get USBLOG and contact to service headquarters.
* : Only HDD standard model
Since the USB log immediately after
occurrence is needed for analysis,
please give me cooperation of the
acquisition.
When there is no Flash for FAX
data and the operation of the secu-
rity kit becomes OFF, it has to
change reading from HDD to SSD.
F51X,
F52X,
F53X,
F55X,
F56X,
F57X
Abnormality detecting in a JOB execution part (1) Initialize HDD and perform an operation check.
(FULL of U024) *
(2) U021 Main backup initialization is carried out and an operation
check is performed.
(3) Exchange Main PWB, and perform an operation check.
(4) Exchange HDD, and perform an operation check. *
(5) Get USBLOG and contact to service headquarters.
* : Only HDD standard model
Since the USB log immediately after
occurrence is needed for analysis,
please give me cooperation of the
acquisition.
F58X,
F59X,
F5AX,
F5BX,
F5CX,
F5DX,
F5EX
Abnormality detecting in the various-services
Management Department
(1) Initialize HDD and perform an operation check.
(FULL of U024) *
(2) U021 Main backup initialization is carried out and an operation
check is performed.
(3) Exchange Main PWB, and perform an operation check.
(4) Exchange HDD, and perform an operation check. *
(5) Get USBLOG and contact to service headquarters.
* : Only HDD standard model
Since the USB log immediately after
occurrence is needed for analysis,
please give me cooperation of the
acquisition.
F5DX: In particular, in case X is
9,A,B,C and D) occurs in Fax
receiving process and URDS rela-
tion process.
Check the sending data from PC
side in time of occurrence.
Num-
ber
Contents Verification procedure / check point Remarks