2WA/2NJ/2RK-2
6-40
Adjustment: LSU Out Left
1.Select the item to adjust.
2.Press the [System Menu] key.
3.Press the [Start] key to output a test pattern.
4.Press the [System Menu] key.
5.Change the setting value by using [+] [-] key or the numeric keypad.
For the test pattern 1, increase the value.
For the test pattern 2, decrease the value.
* :When the setting value is increased, the image moves to right, and it moves to left when the
setting value is decreased.
Figure 6-5
6.Press the [Start] key to set the setting value.
Precautions
Check the copy image after the adjustment. If the image is still incorrect, adjust the following in
the maintenance mode.
U034 < U067(P.6-57) < U072(P.6-63)
Items Contents Setting
range
Data
variation
Initial
setting
MPT Adjust the center line for the MP tray -3.0 to 3.0 0.1mm 0
Cassette1 Adjust the center line for cassette 1 feed -3.0 to 3.0 0.1mm 0
Cassette2 Adjust the center line for cassette 2 feed -3.0 to 3.0 0.1mm 0
Cassette3 Adjust the center line for cassette 3
(Optional unit) feed
-3.0 to 3.0 0.1mm 0
Cassette4 Adjust the center line for cassette 4
(Optional unit) feed
-3.0 to 3.0 0.1mm 0
Cassette5 Adjust the center line for cassette 5
(Optional unit) feed
-3.0 to 3.0 0.1mm 0
Cassette6 Adjust the center line for cassette 6
(Optional unit) feed
-3.0 to 3.0 0.1mm 0
Cassette7 Adjust the center line for cassette 7
(Optional unit) feed
-3.0 to 3.0 0.1mm 0
Duplex Adjusting the center line when duplex
copying (Back page)
-3.0 to 3.0 0.1mm 0
Center line of printing
(within ± 2.0 mm)
Correct image
Output
example 1
Output
example 2