Adjusts the center line for the table scanning.
Purpose
Adjusted if there is a regular error between the center lines of the copy image and original.
Adjustment
1.Press the [Start] key.
2.Press the [System Menu] key.
3.Place an original and press the [Start] key to make a test copy.
4.Press the [System Menu] key.
*: Initial setting value is a reference value as the value changes by the adjustment at the production.
1.Change the setting value by using [+] [-] key or the numeric keypad.
For the copy example 1, decrease the value.
For the copy example 2, increase the value.
* :When the setting value is increased, the image moves to left, and it moves to right when the
setting value is decreased.
Figure 6-10
2.Press the [Start] key to set the setting value.
Precautions
Check the copy image after the adjustment. If the image is still incorrect, adjust the following in
the maintenance mode.
U034(P.6-38) > U065(P.6-54) > U067
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U067 Adjusting the table scanning center line
(Message: Adjust Table Center)
Items Contents Setting range Data
variation
Initial
setting
Front Adjusts the scanner center line -60 to 60 0.085 mm 0
Original Copy
example 1
Copy
example 2
Center line of the copy image (within ± 2.0 mm)