2WA/2NJ/2RK-2
6-56
Contents
Adjusts the leading edge timing for the table scanning.
Purpose
Executed if there is a regular error between the leading edges of the copy image and original.
Adjustment
1.Press the [Start] key.
2.Press the [System Menu] key.
3.Place an original and press the [Start] key to make a test copy.
4.Press the [System Menu] key.
5.Change the setting value by using [+] [-] key or the numeric keypad.
For the copy example 1, increase the value.
For the copy example 2, decrease the value.
* :When the setting value is increased, the image moves forward, and it moves backward
when the setting value is decreased.
Figure 6-9
6.Press the [Start] key to set the setting value.
Precautions
Check the copy image after the adjustment. If the image is still incorrect, adjust the following in
the maintenance mode.
U034(P.6-38) > U065(P.6-54) > U066
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U066 Adjusting the table scanning timing
(Message: Adjust Table Leading Edge Timing)
Items Contents Setting range Data
variation
Initial
setting
Front Adjusts the scanner leading edge margin. -30 to 30 0.16 mm 0
Original Copy
example 1
Copy
example 2
Leading edge registration of the copy image (+1.0/-1.5 mm or less)