2WA/2NJ/2RK-2
6-76
Contents
Set the secondary transfer control voltage.
Purpose
Change setting if a failure such as faint image, etc. occurs.
Method
1.Press the [Start] key.
2.Select the item to set.
* :The screen for setting is displayed.
Execution: Light/Normal1
1.Select the item to set.
* :The screen for setting is displayed.
Setting: 1st
1.Select the item to set.
2.Change the setting value by using [+] [-] key or the numeric keypad.
3.Press the [Start] key and then fix the setting value.
U106 Secondary transfer voltage adjustment
(Message: Adjust 2nd Transfer Roller Output)
Items Contents
Light/Normal1 Transfer control value for Light and Normal1
Normal2/3 Transfer control value for Normal 2/ 3
Heavy1- 3 Transfer control value for Heavy 1 to 3
Heavy4/5 Transfer control value for Heavy 4/ 5
OHP Transfer control value for Transparency
Bias Bias setting
Items Contents
1st Surface transfer control value at full speed
2nd Back side transfer control value at full speed
Items Contents Setting range Data
varia-
tion
Initial setting
90
ppm
80
ppm
70
ppm
Width=105 Setting that paper width is equal to 105 0 to 255 1 162 154 143
Width=210 Setting that paper width is equal to 210 0 to 255 1 158 150 140
Width=297 Setting that paper width is equal to 297 0 to 255 1 149 142 133