Replacing corotron wire
Caution:
There can be a high build-up of static charge when vacuuming the toner spill.
Always use an industrial vacuum cleaner with a grounded suction tube, rubber nozzle
and filter set for fine dust. For larger toner quantities, the industrial vacuum cleaner must
be explosion-proof.
Attention:
Each time the corotron wires are replaced, the corotron slide-in unit must be cleaned.
To Replace the Corotron Wire
#
Proceed as follows:
Caution
Do not touch or damage the corotron wires.
Wear the gloves provided in the packaging.
Open packaging with the new corotron wires.1.
Pick up the change receiver for
corotron wires.
2.
Chapter 9 - Replacing Expendables428