D-32 Parameter Reference
AC30V series Variable Speed Drive
Energy Meter
Monitor::Energy Meter
Parameters::Motor Control::Energy Meter
This feature measures the electrical energy used by the motor.
PNO Parameter Descriptions
0380 Power kW
This diagnostic shows the power being delivered to the load in kilowatts.
0381 Power HP
This diagnostic shows the power being delivered to the load in horsepower.
0382 Reactive Power
This diagnostic shows the reactive power being delivered to the load in kilo volt-amperes reactive.
0383 Energy kWh
This diagnostic shows the total energy consumed by the load in kilowatt hours.
0385 Power Factor Est
This diagnostic shows the power factor estimate (between 0 and 1).
0386 Power Factor Angle Est
This diagnostic shows the power factor angle estimate.
0389 Reset Energy Meter
When Reset Energy Meter is set to TRUE, the Energy KWh parameter is reset to zero automatically when the maximum value is
reached.
When Reset Energy Meter is set to FALSE, the Energy KWh parameter is held at the maximum value when the maximum value
has been reached
Changing this from FALSE to TRUE at anytime will cause the Energy KWh parameter to be reset to zero.
www.comoso.com

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485

Related product manuals