D-46 Parameter Reference
AC30V series Variable Speed Drive
General Purpose IO
Monitor::Inputs and Outputs
Parameters::Option IO::General Purpose IO
The General Purpose IO parameters configure the use of the three IO Options, (Error! Bookmark not defined.). This group of parameters is
only visible when an IO Option is selected.
PNO Parameter Descriptions
1181 Anin 11 Value, (Terminal X21.2)
The input value expressed as a percentage of range, (+/- 100%), following Offset and Scale.
1182 Anin 12 Value, (Terminal X21.3)
The input value expressed as a percentage of range, (+/- 100%), following Offset and Scale.
1183 Anin 13 Value, (Terminal X21.4)
The input value expressed as a percentage of range, (+/- 100%), following Offset and Scale.
1461 Anin 11 Offset
The offset is expressed as a percentage of the hardware range. For example an offset of 10% is equivalent to 1V on the input.
The offset is added to the measured value.
1462 Anin 11 Scale
The scale is a simple multiplication factor. The input voltage is converted to a percentage value. 1461 Anin 11 Offset is added and
the result is multiplied by Scale. The result is presented in parameter
1181 Anin 11 Value
.
1463 Anin 12 Offset
The offset is expressed as a percentage of the hardware range. For example an offset of 10% is equivalent to 1V on the input.
The offset is added to the measured value.
1464 Anin 12 Scale
The scale is a simple multiplication factor. The input voltage is converted to a percentage value. 1463 Anin 12 Offset is added and
the result is multiplied by Scale. The result is presented in parameter
1182 Anin 12 Value
.
1465 Anin 13 Offset
The offset is expressed as a percentage of the hardware range. For example an offset of 10% is equivalent to 1V on the input.
The offset is added to the measured value.
1466 Anin 13 Scale
The scale is a simple multiplication factor. The input voltage is converted to a percentage value. 1465 Anin 13 Offset is added and
the result is multiplied by Scale. The result is presented in parameter
1183 Anin 13 Value
.