Parameter Reference D-19
AC30V series Variable Speed Drive
Control Mode
Setup:: Motor Control::Control & Type:: Control Strategy
Parameters::Motor Control::Control & Type::Control Strategy
The control mode block provides the means for selecting the type of motor and the desired method of controlling the motor.
PNO Parameter Descriptions
0511 Motor Type
Motor type selection parameter
Allows the user to select the type of motor.
Enumerated Value : Motor Type
0 : INDUCTION MOTOR
1 : PMAC (PERMANENT MAGNET) MOTOR
0512 Control Strategy
This parameter will only become visible if an induction motor is selected. If a PMAC motor is selected, the Control Strategy will
automatically be set to Vector Control.
Select control strategy selection parameter.
Allows the user to select the method of controlling the motor.
Enumerated Value : Control Strategy
0 : VOLTS HERTZ CONTROL
1 : VECTOR CONTROL
1533 Control Type
This parameter will only become visible if an induction motor is selected, Control Strategy is set to Vector Control, and the encoder
option is fitted. If the encoder option is not fitted, the control strategy is forced to be sensorless.
It allows the user to choose between sensorless control, and control using encoder feedback.
If an encoder is available, encoder feedback control would normally be the preferred choice as it gives better speed control and
higher performance.
Enumerated Value : Control Strategy
0 : SENSORLESS
1 : ENCODER FEEDBACK
Functional Description
The motor selection is the first step in setting the control mode.
www.comoso.com

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485

Related product manuals