Technical Specifications F-9
AC30V series Variable Speed Drive
INPUT FUSE RATINGS (EUROPE)
Product Code Input Fuse Rating (A) Product Code Input Fuse Rating (A)
NORMAL DUTY NORMAL DUTY
400V BUILD VARIANT 380-480V ±10%, 50/60Hz +5%*
Frame D Frame G
31V-4D0004… 10A 31V-4G0045 63A
31V-4D0005… 10A 31V-4G0060 80A
31V-4D0006… 10A 31V-4G0073 100A
31V-4D0008… 10A
Frame H
31V-4D0010… 12A 31V-4H0087 125A
31V-4D0012… 16A 31V-4H0105 150A
Frame E
31V-4H0145 200A
31V-4E0016… 20A
Frame J
31V-4E0023… 25A 31V-4J0180 250A
Frame F
31V-4J0205 315A
31V-4F0032… 32A 31V-4J0260 400A
31V-4F0038… 40A