Safe Torque Off 6-6
AC30V series Variable Speed Drive
Note: all values quoted in this table are valid only when the two STO user inputs are driven independently. This is as required by EN ISO
13849-1 category 3. See the Alignment to European Standards section in this chapter for the required architecture which must be used
throughout the machine design relevant to the drive under consideration.
EMC Specification
In addition to the mandatory requirements of EN61800, the STO functionality has been subjected to testing for immunity at higher levels. In particular
the STO function (only) has been tested for radiated immunity according to EN62061:2005 Annex E up to 2.7GHz which includes frequencies used by
mobile telephones and walkie-talkies.
www.comoso.com

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485