Parameter Reference D-161
AC30V series Variable Speed Drive
Power Dependent Parameter Defaults
The tables below shows the parameters whose default value is dependent on the Power Stack.
PNO
NONE
3.5 A 400 V
4.5 A 400 V
5.5 A 400 V
7.5 A 400 V
10.0 A 400 V
12.0 A 400 V
16.0 A 400 V
23.0 A 400 V
32.0 A 400 V
38.0 A 400 V
Brake Resistance
Ohms
0251
100
100
100
100
100
100
100
52
52
26
26
Brake Rated Power
kW
0252
0.1
0.11
0.15
0.22
0.3
0.4
0.55
0.75
1.1
1.5
1.8
mras coupling kc
0278
14.9874
14.9874
11.5288
6.2448
2.9363
1.7128
2.6526
2.6526
1.314
0.9592
0.7105
mras coupling ti
s
0279
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
mras adaptive kc
0280
4.3851
4.3851
2.6283
1.5279
0.7514
0.5727
0.6854
0.6854
0.3198
0.3484
0.1792
mras adaptive ti
s
0281
0.112
0.112
0.112
0.112
0.112
0.112
0.112
0.112
0.112
0.112
0.112
mras adaptive td
s
0282
0.1094
0.1094
0.1094
0.1367
0.1367
0.1367
0.276
0.276
0.3036
0.3795
0.506
mras ls low threshold
Hz
0294
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
mras ls high threshold
Hz
0295
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
mras adaptive loop bwdt
Hz
0300
4
4
4
4
4
4
4
3
3
2
2
i lim vhz p gain
0308
2
2
2
2
2
2
2
2
2
2
2
i lim vhz i gain
0309
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.3
0.3
Search Volts
%
0314
9
9
9
9
9
9
9
9
9
9
9
Search Boost
%
0315
40
40
40
40
40
40
40
40
40
15
15
Search Time
0316
5
5
5
5
5
5
5
10
10
15
15
Flying Reflux Time
0318
3
3
3
3
3
3
3
3
3
4
4
error scaler
%
0322
200
200
200
200
200
200
200
200
200
175
175
DC Inj Deflux Time
0324
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
1
1
DC Inj Frequency
Hz
0325
9
9
9
9
9
9
9
9
9
9
9
DC Pulse Time
0327
2
2
2
2
2
2
2
2
2
2
2
Final DC Pulse Time
0328
1
1
1
1
1
1
1
1
1
3
3
DC Current Level
%
0329
3
3
3
3
3
3
3
2.5
2.5
1.75
1.75
DC Inj Base Volts
%
0331
100
100
100
100
100
100
100
100
100
100
100
stb gain
0366
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
stb trim limit
Hz
0368
1
1
1
1
1
1
1
1
1
0.75
0.75
Stack Frequency
kHz
0412
4
4
4
4
4
4
4
4
4
4
4
Deflux Delay
0414
1
1
1
1
1
1
1
1
1
1
1
Fixed Boost
%
0447
0
0
0
0
0
0
0
0
0
0
0
auto boost tc
0449
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.3
0.3
Rated Motor Current
A
0455
1.56
1.56
2.88
4.9
6.5
8.4
9.04
14.6
20
27
26.4
Base Voltage
V
0456
400
400
400
400
400
400
400
400
400
400
400
Base Frequency
Hz
0457
50
50
50
50
50
50
50
50
50
50
50
Nameplate Speed
RPM
0459
1400
1400
1420
1420
1420
1420
1445
1450
1460
1470
1460
Motor Power
kW
0460
1.1
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18
Power Factor
0461
0.71
0.71
0.7
0.78
0.8
0.8
0.8
0.83
0.86
0.87
0.88
100% Speed in RPM
RPM
0464
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
Acceleration Time
0486
10
10
10
10
10
10
10
10
10
10
10
Deceleration Time
0487
10
10
10
10
10
10
10
10
10
10
10
Symmetric Time
0489
10
10
10
10
10
10
10
10
10
10
10
total inertia
kgm²
0590
0.0014
0.0014
0.0014
0.0035
0.05
0.0112
0.0176
0.0176
0.0236
0.0603
0.0754
Stall Time
0907
90
90
90
90
90
90
90
90
90
90
90
Max VDC Ripple
V
0913
50
50
50
70
70
80
80
85
85
80
80
VDC Ripple Trip Delay
0914
90
60
60
60
60
60
60
60
60
60
60
stack voltage
0985
1
1
1
1
1
1
1
1
1
1
1
frame size
0986
4
4
4
4
4
4
4
5
5
6
6
mras motor inertia
kgm²
1249
0.0014
0.0014
0.0014
0.0035
0.05
0.0112
0.0176
0.0176
0.0236
0.0603
0.0754
Nameplate Mag Current
A
1550
0.88
0.88
1.65
2.45
3.12
4.03
4.34
6.51
8.16
10.65
10.03