Parameter Reference D-93
AC30V series Variable Speed Drive
Real Time Clock
Parameters::Device Manager::Real Time Clock
PNO Parameter Descriptions
1186 Time and Date
Time and Date in the format yyyy/mm/dd hh:mm:ss
Functional Description
IO Option Fitted with Real Time Clock
When an IO Option is fitted, (part number 7004-01-00 or 7004-02-00), this parameter reports the time from the associated Real Time Clock
hardware. On receiving an IO Option from the factory the time is not set and the value will be fixed at 1970/01/01 00:00:00. To set the correct
time write to parameter 1186. Once set the RTC hardware on the IO option will maintain the time even when power to the drive is removed.
No IO Option
When no IO Option is fitted this parameter may be used as the destination of a broadcast time from a communications master.