EasyManuals Logo

Parker AC30 series User Manual

Parker AC30 series
453 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
6-5 Safe Torque Off
AC30V series Variable Speed Drive
Safety Specification
As assessed to EN ISO13849-1 and EN61800-5-2 the AC30V has the following related safety values:-
Criterion Requirement Value achieved
SIL3
For type A subsystems, HFT = 1:
SFF ≥ 60%
SFF = 99%
SIL3 10
-7
≥ PFH ≥ 10
-8
PFH = 2.3 x 10
-9
SIL Capability - 3
PLe Category 3; PFH 4,29 x 10
-8
PFH = 2.3 x 10
-9
PLe 30 years ≤ MTTFd < 100 years MTTFd = 100 years
1
PLe DC = medium DC = Medium
Mission Time 20 years 20 years
Fault Reaction Function - Latched STO
2
1
EN ISO13849 limits MTTFd to 100 years.
2
A detected fault in the STO circuit causes STO to become active, and remain active until after a power cycle.
www.comoso.com

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485