Parameter Reference D-37
AC30V series Variable Speed Drive
PNO Parameter Descriptions
0398 iq
Current in the torque axis (Vector Control)
0399 Actual Torque
Calculated torque, based on the Iq current.
0400 Actual Field Current
Calculated field, based on the Id current.
0401 Motor Current Percent
This diagnostic shows the level of rms line current being drawn from the drive as a percentage of the rated current of the relevant
motor definition.
0402 Motor Current
This diagnostic shows the level of rms line current in Amps being drawn from the Drive.
0403 100% Stack Current A
This diagnostic indicates the stack rating in Amps. This reduces as a function of pwm switching frequency.
0404 Stack Current (%)
Stack current percentage.
0405 Motor Terminal Volts
Volts between motor phases in Vrms.
0406 CMTemperature
Temperature of Control Module in
o
Centigrade.
0407 Heatsink Temperature
Power stack heatsink temperature in
o
Centigrade.
0408 Elec Rotor Speed
Mechanical speed (shaft speed in
rev
/
s
) x number of motor pole pairs. This parameter is not filtered.
0409 Heatsink OT Trip
Heatsink Overtemp Trip Level.
0410 Heatsink OT Warning
Heatsink Overtemp Warning level.
0411 Heatsink Hot Warning
Heatsink Hot Warning Level.